Oracle Data Recorder

It's Amazing!
We took our renowned Power Analyzer Pro with
Its Precision and Accuracy
      Its Multitude of Features
           Its Versability and Flexibility
and shrunk it down to this...
New 200A version Now Available!
A tiny 1" x 1.8" lightweight unit with the most power and functionality of any R/C data recorder.

Records up to 10 different parameters: Volts, Amps, Watts, AmpHrs, WattHrs, two (2) Temperatures, RPM, Throttle and an Aux input.  The RPM Phase sensor with no magnets or optics, just a connection to one wire of your brushless motor.

User configurable for Sample Rate, Channels to record and much more to get just get the data that you need. Records from 20 minutes to over 10 days worth of data (depending upon sample rate and number of channels recorded).

Use your existing Power Analyzer Pro or POWERLink USB Adapter to configure the Oracle or download and graph your recorded data using the versatile and feature rich PowerPROview software.

Save, graph and analyze your data with the powerful features of the PowerPROview program available as a free download from our web site.

Even more measurements can be made with add on modules soon to be available:

the Servo Monitor Module adds Servo voltage and current, additional inputs for temps or Aux analog inputs, the Altimeter Module adds altitude, and other modules will be available for an array of measurements.


No more guessing about as to the performance of your model in flight. Use the Oracle Data Recorder, the device that Knows All, Sees All, and Tells All.

Its broad measurement range and high resolution make it just as useful on any model.

Available with Deans connectors or with wires.


The Oracle Data Recorder is a precision measurement instrument that allows you to accurately measure and record all the performance information from your electric model.

Records Volts, Amps, Watts, WattHrs, AmpHrs, RPM, Throttle, two (2) Temperatures, and Aux Input.
Recording times from 20 minutes to over 10 days
High resolution
Holds multiple recordings at one time 
Factory Calibrated. Our units are the standard for accuracy for R/C meters and recorders.
User updatable and expandable for future enhancements.
Lowest resistance/voltage drop of any other RC Data Recorder.
We use a true current shunt to get the most accurate reading possible.

 
Technical Specifications
MR-DR-60100
MR-DR-60200
Input Specifications
Minimum Maximum Minimum Maximum
Input Voltage 5 Volts 60 Volts 5 Volts 60 Volts
0 Volts 0 Volts
Current -30 Amps 100 Amps1 -60 Amps 200 Amps2
Display Range
Voltage
60 Volts
60 Volts
Current
-30 to 100 Amps
-60 to 200 Amps
Power
9999 Watts
9999 Watts
Amp-Hours
±999.999 AH
±999.999 AH
Watt-Hours
±9999.9 WH
±9999.9 WH
Temperature Channels 1 & 2
0°C to 130°C or 32°F to 266°F (user selectable)
0°C to 130°C or 32°F to 266°F (user selectable)
RPM
60,000 (up to seven blades/14 poles)
60,000 (up to seven blades/14 poles)
Throttle
10us to 2.5ms
10us to 2.5ms
Resolution
Voltage
0.005 V
0.005 V
Current
0.010 A
0.020 A
Watts
1 W
2 W
Amp-Hours
0.001 AH
0.002 AH
Watt-Hours
0.1 WH
0.2 WH
Temperature Channels 1 & 2
0.1°C or F
0.1°C or F
RPM
25, 50, or 100 (user selectable)
25, 50, or 100 (user selectable)
Throttle
10us
10us
Auxiliary Analog Input
160µV
160µV
Sample Rate
229.4ms (4.4 samples/sec) Maximum
58.5Secs (1 sample/Min) Minimum
229.4ms (4.4 samples/sec) Maximum
58.5Secs (1 sample/Min) Minimum
Recording Time 20 minutes to over 10 days 20 minutes to over 10 days
Accuracy
Offset
±1 count
±1 count
Voltage
±0.1% of reading
±1 count
±0.1% of reading
±1 count
Current
±0.1% of reading
±1 count
±0.1% of reading
±1 count
Temperature Channels 1 & 2
±1°C or ±1.8°F
±1°C or ±1.8°F
RPM
±0.1% of reading
±1 count
±0.1% of reading
±1 count
Throttle
±1 count
±1 count
Auxiliary Analog Input
±1 count
±1 count
Other
Current Shunt Resistance
0.0002 Ohms
0.0002 Ohms
Physical Description
Board Dimensions (HxLxW)
9mm x 46mm x 26mm
(0.35" x 1.81" x 1.02")
9mm x 46mm x 26mm
(0.35" x 1.81" x 1.02")
Weight w/ Deans
14g (0.49oz)
14g (0.49oz)
Weight w/ Wires
28g (0.98oz) (2 1/4" wire)
28g (0.98oz) (2 1/4" wire)
1Max duration at 100A < 30 secs
2Max duration at 100A < 30 secs, 150A < 10 secs, 200A < 5 secs

Purchase the Oracle Data Recorder  
Requires:
Power Analyzer Pro or POWERLink USB Adapter to connect to PC computer for data download and configuration.
$41.95
MR-DR-60100-D
Oracle w/Deans
Unavailable
MR-DR-60100-W
Oracle w/Wires
$48.95
MR-DR-60200-D
Oracle w/Deans
MR-DR-60200-W
Oracle w/Wires
Unavailable


Wondering what the difference is between the Oracle and the Power Analyzers? We've got a comparison chart just for you.

Purchase the Oracle Standard Package
The Oracle Standard Package includes:
1 Oracle Data Recorder (MR-DR-60100 or MR-DR-60200)
1 Temp Sensor (MR-TEMP-001)
1 RPM Phase Sensor (MR-RPM-002)
1 POWERLink USB Adapter (MR-USB-001)
  w/USB Cable
$62.95
MR-DR-60100-D-S
Oracle Standard Package w/Deans
Unavailable
MR-DR-60100-W-S
Oracle Standard Package w/Wires
$68.95
MR-DR-60200-D-S
Oracle Standard Package w/Deans
MR-DR-60200-W-S
Oracle Standard Package w/Wires
Unavailable

The Oracle keeps you up-to-date with our latest innovations. As always, Medusa Research will offer new versions of the PowerPROview software for the PC FREE when new features are added. In addition to the free PC software upgrades, the Oracle now boasts the ability to upgrade the software inside itself. The user can perform the upgrade in their own home by downloading the updates from our website and reprogramming the Oracle through its USB connection. We call this feature ISP for In System Programming.

ISP also allows the Oracle Data Recorder you buy today to be compatible with new Oracle accessories and features that we may develop in the future.
 




BECs OptoCouplers ESCs Motors Power Analyzers